About Us
Company Profile
Message From CMD
Vision
History
Leadership Team
Network
Warehouse
Socially Responsible
CSR Policy
Nomination and Remuneration Policy
Annual Return
Products
Wires & Cables
Transformers
Towers and Conductors
Motors
Variable Frequency Drives (VFD)
Switchgear
Lighting
Jointing Kits
Modular Switches
Fans
Water Heaters
Customers
Suppliers
E-Business
News
Careers
Why Shree NM
Training and Development
Employee Engagement
Join Us
Contact Us
India Map
Business Enquiry
About Us
Company Profile
Message From CMD
Vision
History
Leadership Team
Network
Warehouse
Socially Responsible
CSR Policy
Nomination and Remuneration Policy
Annual Return
Products
Wires & Cables
Transformers
Towers and Conductors
Motors
Variable Frequency Drives (VFD)
Switchgear
Lighting
Jointing Kits
Modular Switches
Fans
Water Heaters
Customers
Suppliers
E-Business
News
Careers
Why Shree NM
Training and Development
Employee Engagement
Join Us
Contact Us
India Map
Business Enquiry
Home
Schneider Electric
Price List
Page 18()
Price List is last updated on
01-05-2012
With Electronic Trip Units (up Based ) Micrologic 6A
Ics = 100% Icu a sper IEC 60947-2
Suitable for Isolation
Current measurements (Phase & neutral, Average, Highest of phases, Ground fault current, Maximeter / Minimeter, Current unbalance between phases)
Adjustable overload from Ir 0.36 to 1 x In and tr = 0.5 - 16 s
Adjustable short circuite from Isd 1.5 - 10 x Ir and tsd I2 tON / OFF 0.1 - 0.4s
Adjustable earth fault 0.4 - 1 x In ( for in = 40A) and tg I2 tON / OFF 0.1 - 0.4s
Instantaneous protection Ii 1.5 x in - 15 x in (40 - 160A), 12 X In (250 - 400A ) and 11 x in (630A)
Innovative front indication LEDs (Ready , Overload pre-alarm & Overload)
Fault distinction on the display of trip unit (type of fault, interrupted fault current and faulty phase)
Zone Selective Interlocking (ZSI) as standard
Breaking Capacity enhancement upto 150kA with a higher capacity upstream (Cascading)
Adjustable neutral protection - N , N / 2, OFF and oversized neutral (standard feature) for 4Pole MCCB.
Breaking Capacity lcs as per IEC 60947-2
Reted Current
Three Pole Reference
Unit MRP [Rs.]
Four Pole Reference
Unit MRP [Rs.]
Action
25 kA
40 A
LV429014X62A40
29825
LV429015X62A40
33415
25 kA
100 A
LV429014X62A100
29825
LV429015X62A100
33415
25 kA
160 A
LV430390X62A160
33055
LV430395X62A160
36915
25 kA
250 A
LV431390X62A250
36495
LV431395X62A250
43310
36 kA
40 A
LV429003X42A40
30625
LV429008X62A40
34265
36 kA
100 A
LV429003X62A100
30625
LV429008X62A100
34265
36 kA
160 A
LV430403X62A160
34155
LV430408X62A160
39450
36 kA
250 A
LV431403X62A250
37590
LV431408X62A250
46200
36 kA
400 A
LV432413X63A400
42945
LV432415X63A400
48900
36 kA
630 A
LV432813X63A630
46400
LV432815X63A630
58790
50 kA
40 A
LV429006X62A40
33180
LV429011X62A40
36890
50 kA
100 A
LV429006X62A100
33180
LV429011X62A100
36890
50 kA
160 A
LV430406X62A160
37270
LV430411X62A160
41365
50 kA
250 A
LV431406X62A250
39895
LV431411X62A250
48195
50 kA
400 A
LV432403X63A400
44250
LV432408X63A400
53570
50 kA
630 A
LV432803X63A630
49060
LV432808X63A630
63395
70 kA
40 A
LV429004X62A40
36525
LV429009X62A40
41590
70 kA
100 A
LV429004X62A100
36525
LV429009X62A100
41590
70 kA
160 A
LV430404X62A160
45305
LV430409X62A160
48915
70 kA
250 A
LV431404X62A250
45395
LV431409X62A250
70900
70 kA
400 A
LV432404X63A400
58000
LV432409X63A400
72960
70 kA
630 A
LV432804X63A630
59500
LV432809X63A630
81300
Micrologic 6 E (Embedded Metering)
Current Measurements ( Phase & netural, Average, Highest of Phases, Ground Fault current , Maximeter / Minimeter , Current Unbalance between Phases)
Voltage Measurements ( Phases - Phases & Phases - neitral , Average ,Ph-Ph & Ph - N voltage unbalance)
Frequency Measurements
Power Qulity Indicator ( Total Harmoic Distortion for Current and Voltage )
Power Measurements ( Active Reactive and Apparent Power , total and per phase and power Factor and cos (phi)
Demand Current and Power Measurement ( Demand Values ,total & per phase , Maximum Demand)
Energy ,Metering (Active Reactive and Apprent energy ,total and per phase)
Indication Alarm and Histories( Indication of fault types , Alarms for high/low threshold, operting histories & time stamped tables)
Maintenance Indicators ( Operation ,trip and alarm counters. Operating Hours Counter ; Contact wear ,load profile and thermal image)
Communication ( Modbus with add on module)
Action
25 kA
40 A
LV429014X62A40
29825
LV429015X62A40
33415
25 kA
100 A
LV429014X62A100
29825
LV429015X62A100
33415
25 kA
160 A
LV430390X62A160
33055
LV430395X62A160
36915
25 kA
250 A
LV431390X62A250
36495
LV431395X62A250
43310
36 kA
40 A
LV429003X42A40
30625
LV429008X62A40
34265
36 kA
100 A
LV429003X62A100
30625
LV429008X62A100
34265
36 kA
160 A
LV430403X62A160
34155
LV430408X62A160
39450
36 kA
250 A
LV431403X62A250
37590
LV431408X62A250
46200
36 kA
400 A
LV432413X63A400
42945
LV432415X63A400
48900
36 kA
630 A
LV432813X63A630
46400
LV432815X63A630
58790
50 kA
40 A
LV429006X62A40
33180
LV429011X62A40
36890
50 kA
100 A
LV429006X62A100
33180
LV429011X62A100
36890
50 kA
160 A
LV430406X62A160
37270
LV430411X62A160
41365
50 kA
250 A
LV431406X62A250
39895
LV431411X62A250
48195
50 kA
400 A
LV432403X63A400
44250
LV432408X63A400
53570
50 kA
630 A
LV432803X63A630
49060
LV432808X63A630
63395
70 kA
40 A
LV429004X62A40
36525
LV429009X62A40
41590
70 kA
100 A
LV429004X62A100
36525
LV429009X62A100
41590
70 kA
160 A
LV430404X62A160
45305
LV430409X62A160
48915
70 kA
250 A
LV431404X62A250
45395
LV431409X62A250
70900
70 kA
400 A
LV432404X63A400
58000
LV432409X63A400
72960
70 kA
630 A
LV432804X63A630
59500
LV432809X63A630
81300