Shree NM Electricals Limited
  • Home

 Price List is last updated on  

Motor Circuit Breakers

disjoncteur-gv2me01.jpg
  • Conforming  to IEC 60947-2-3-4
  • Thermal magnetic circuit breakers rage form 0.1-220 Amps
  • High Breaking capacity up to 100  kA
  • Conformity to International Standards -UL,CSA,CE
  • Wide range of accessories
  • S-shaped busbar for side-by-side connection with 40-65A Contactor
Breaking Capacity at 415 V 50 Hz Motor Power AC3** kW Motor Power AC3** hP Thermal Protection Adjustment Range Referance Unit MRP [Rs.] Action
100 kA - - 0.1 - 0.16 GV2ME01 2485 Details
100 kA 0.06 - 0.16 - 0.25 GV2ME02 2485 Details
100 kA 0.09 - 0.25 - 0.40 GV2ME03 2485 Details
100 kA 0.18 - 0.40 - 0.63 GV2ME04 2820 Details
100 kA 0.37 0.5 0.63 - 1.0 GV2ME05 2820 Details
100 kA 0.55 0.75 1.0 - 1.6 GV2ME06 2830 Details
100 kA 0.75 1 1.6 - 2.5 GV2ME07 2830 Details
100 kA 1.1 2 2.5 - 4 GV2ME08 2930 Details
100 kA 2.2 3 4 - 6.3 GV2ME10 2930 Details
100 kA 3 5.5 6 - 10 GV2ME14 2955 Details
15 kA 5.5 7.5 9 - 14 GV2ME16 3420 Details
15 kA 7.5 10 13 - 18 GV2ME20 3675 Details
15 kA 9 12.5 17 - 23 GV2ME21 4065 Details
15 kA 11 15 20 - 25 GV2ME22 4230 Details
10 kA 15 20 24 - 32 GV2ME32 7760 Details
100 kA - - 0.1 - 0.16 GV2P01 3545 Details
100 kA 0.06 - 0.16 - 0.25 GV2P02 3545 Details
100 kA 0.09 - 0.25 - 0.40 GV2P03 3570 Details
100 kA 0.18 - 0.40 - 0.63 GV2P04 3715 Details
100 kA 0.37 0.5 0.63 - 1.0 GV2P05 3920 Details
100 kA 0.55 0.75 1.0 - 1.6 GV2P06 4100 Details
100 kA 0.75 1.0 1.6 - 2.5 GV2P07 4100 Details
100 kA 1.1 2 2.5 - 4 GV2P08 4140 Details
100 kA 2.2 3 4 - 6.3 GV2P10 4140 Details
100 kA 3 5.5 6 -10 GV2P14 4455 Details
100 kA 5.5 7.5 9 - 14 GV2P16 4475 Details
50 kA 7.5 10 13 - 18 GV2P20 4575 Details
50 kA 9 12.5 17 - 23 GV2P21 4885 Details
50 kA 11 15 20 - 25 GV2P22 4925 Details
35 kA 15 20 24 - 32 GV2P32 7930 Details
50 kA - 18.5 30...40 A GV3P40 9490 Details
50 kA - 22 37...50 A GV3P50 10260 Details
50 kA - 30 48...65 A GV3P65 10955 Details
15 kA 37 - 56...80 A GV3ME80 11490 Details

motor Circuit breakers

30-25052010-058505L.gif
  • Conforming to IEC 60947-2-3-4
  • Magnetic circuit breakers rage form 0.1-80A Amps
  • High Breaking capacity up to 100kA
  • Conformity to INternational Standards -IEC,UL,CSA,CE
  • Wide range of accessories
Breaking Capacity at 415 V 50 Hz Motor Power AC3** kW Motor Power AC3** hP Magnetic Protection Rating (A) Referance Unit MRP [Rs.] Action
100 kA 0.09 - 0.4 GV2LE03 2450 Details
100 kA 0.18 - 0.63 GV2LE04 2450 Details
100 kA 0.37 0.5 1 GV2LE05 2450 Details
100 kA 0.55 - 1.6 GV2LE06 2450 Details
100 kA 1.1 1.5 2.5 GV2LE07 2450 Details
100 kA 1.5 2 4 GV2LE08 2450 Details
100 kA 2.2 3 6.3 GV2LE10 2450 Details
100 kA 3 5.5 10 GV2LE14 2450 Details
15 kA 5.5 7.5 14 GV2LE16 2450 Details
15 kA 7.5 10 18 GV2LE20 2805 Details
15 kA 11 15 25 GV2LE22 2805 Details
10 kA 15 20 32 GV2LE32 4835 Details
100 kA 0.09 - 0.4 GV2L03 3235 Details
100 kA 0.18 - 0.63 GV2L04 3235 Details
100 kA 0.37 0.5 1 GV2L05 3235 Details
100 kA 0.55 - 1.6 GV2L06 3235 Details
100 kA 1.1 1.5 2.5 GV2L07 3235 Details
100 kA 1.1 2 4 GV2L08 3235 Details
100 kA 2.2 3 6.3 GV2L10 3235 Details
100 kA 4 5.5 10 GV2L14 3235 Details
50 kA 5.5 7.5 14 GV2L16 3235 Details
50 kA 7.5 10 18 GV2L20 3235 Details
50 kA 11 15 25 GV2L22 3235 Details
50 kA - 18.5 40 GV3L40 7820 Details
50 kA - 22 50 GV3L50 7990 Details
50 kA - 30 65 GV3L65 8255 Details
35 kA 37 - 80 GK3EF80 8835 Details

GV7-R Range Thermal Magnetic (220A,AC3 )

images 1_23.jpg

Breaking Capacity at 415 V 50 Hz* Motor Power AC3** kW Thermal Protection Adjustment Range Referance Unit MRP [Rs.] Action
36 kA 45 60 - 100 GV7RE100 11675 Details
35 kA 75 90 - 150 GV7RE150 16035 Details
35 kA 110 132 - 220 GV7RE220 23650 Details
70 kA 18.5 25 - 40 GV7RS40 12635 Details
70 kA 22 30 - 50 GV7RS50 12635 Details
70 kA 37 48 - 80 GV7RS80 13520 Details
70 kA 45 60 - 100 GV7RS100 13520 Details
70 kA 75 90 - 150 GV7RS150 18165 Details
70 kA 110 132 - 220 GV7RS220 26735 Details